{"id":11407,"date":"2021-07-08T09:27:07","date_gmt":"2021-07-08T07:27:07","guid":{"rendered":"https:\/\/consilab.de\/?page_id=11407"},"modified":"2022-07-11T17:10:03","modified_gmt":"2022-07-11T15:10:03","slug":"dutch-pressure-vessel-test","status":"publish","type":"page","link":"https:\/\/consilab.de\/en\/benefits\/substance-classification\/dutch-pressure-vessel-test\/","title":{"rendered":"Dutch Pressure Vessel Test"},"content":{"rendered":"<p>[vc_row rt_row_background_width=&#8221;fullwidth&#8221; rt_row_content_width=&#8221;default&#8221; rt_row_style=&#8221;default-style&#8221; rt_row_borders=&#8221;&#8221; rt_row_shadows=&#8221;&#8221; rt_row_paddings=&#8221;true&#8221; rt_bg_effect=&#8221;classic&#8221; rt_bg_image_repeat=&#8221;repeat&#8221; rt_bg_size=&#8221;cover&#8221; rt_bg_position=&#8221;right top&#8221; rt_bg_attachment=&#8221;scroll&#8221; rt_bg_video_format=&#8221;self-hosted&#8221;][vc_column width=&#8221;1\/3&#8243; rt_column_shadow=&#8221;&#8221; rt_bg_image_repeat=&#8221;repeat&#8221; rt_bg_size=&#8221;auto auto&#8221; rt_bg_attachment=&#8221;scroll&#8221; class=&#8221;download&#8221; rt_bg_color=&#8221;&#8221; rt_bg_overlay_color=&#8221;&#8221; offset=&#8221;vc_hidden-sm vc_hidden-xs&#8221; css=&#8221;.vc_custom_1529335398592{padding-bottom: 0px !important;}&#8221; rt_padding_bottom=&#8221;0&#8243;][vc_widget_sidebar sidebar_id=&#8221;rt-theme-20-common-sidebar&#8221;][\/vc_column][vc_column width=&#8221;2\/3&#8243; rt_column_shadow=&#8221;&#8221; rt_bg_image_repeat=&#8221;repeat&#8221; rt_bg_size=&#8221;auto auto&#8221; rt_bg_attachment=&#8221;scroll&#8221; class=&#8221;maincontent&#8221; rt_bg_color=&#8221;&#8221; rt_bg_overlay_color=&#8221;&#8221; css=&#8221;.vc_custom_1531993670525{padding-bottom: 2em !important;}&#8221;][vc_column_text el_class=&#8221;redborderleft&#8221;]<\/p>\n<h1>Dutch pressure vessel test: UN Series E, Test E.2<\/h1>\n<p>For the test, the test substance is heated in a pressure vessel, which is closed using aperture discs with orifices of various diameters. The pressure vessel also has a bursting disc, rated to burst at 620 \u00b1 60 kPa. This method is used to determine whether the substance can decompose itself under intense heat.<\/p>\n<p>The apparatus consists of a pressure vessel with orifice plate and bursting disc, which is inserted into a heating and protection device (Figure 1).<\/p>\n<table width=\"642\">\n<tbody>\n<tr>\n<td width=\"425\"><strong>Result<\/strong><\/td>\n<td width=\"217\"><strong>Classification according to UN Test E.2<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"425\">Rupture of the disc with an orifice of 9.0 mm or greater and a sample mass of 10.0 g.<\/td>\n<td width=\"217\">\u201cViolent\u201d<\/td>\n<\/tr>\n<tr>\n<td width=\"425\">No rupture of the disc with an orifice of 9.0 mm but rupture of the disc with an orifice of 3.5 mm or 6.0 mm and a sample mass of 10.0 g.<\/td>\n<td width=\"217\">\u201cMedium\u201d<\/td>\n<\/tr>\n<tr>\n<td width=\"425\">No rupture of the disc with an orifice of 3.5 mm and a sample mass of 10.0 g but rupture of the disc with an orifice of 1.0 mm or 2.0 mm and a sample mass of 10.0 g or rupture of the disc with an orifice of 1.0 mm and a sample mass of 50.0 g.<\/td>\n<td width=\"217\">\u201cLow\u201d<\/td>\n<\/tr>\n<tr>\n<td width=\"425\">No rupture of the disc with an orifice of 1.0 mm and a sample mass of 50.0 g.<\/td>\n<td width=\"217\">\u201cNo<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div id=\"attachment_11410\" style=\"width: 710px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/consilab.de\/wp-content\/uploads\/2021\/07\/Dutch-Pressure-Vessel-Test.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11410\" class=\"wp-image-11410 size-full\" src=\"https:\/\/consilab.de\/wp-content\/uploads\/2021\/07\/Dutch-Pressure-Vessel-Test.jpg\" alt=\"\" width=\"700\" height=\"1233\" srcset=\"https:\/\/consilab.de\/wp-content\/uploads\/2021\/07\/Dutch-Pressure-Vessel-Test.jpg 700w, https:\/\/consilab.de\/wp-content\/uploads\/2021\/07\/Dutch-Pressure-Vessel-Test-199x350.jpg 199w, https:\/\/consilab.de\/wp-content\/uploads\/2021\/07\/Dutch-Pressure-Vessel-Test-581x1024.jpg 581w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/a><p id=\"caption-attachment-11410\" class=\"wp-caption-text\">Figure 1: Apparatus for testing the sensitivity of substances to intense heat under defined confinement (UN Manual, page 263)<\/p><\/div>\n<p>(A)\u00a0\u00a0\u00a0 Bursting disc<br \/>\n(B)\u00a0\u00a0\u00a0 Nozzle plate<br \/>\n(C)\u00a0\u00a0\u00a0 Sample (10 g or 50 g)<br \/>\n(D)\u00a0\u00a0\u00a0 Teclu burner<br \/>\n(E)\u00a0\u00a0\u00a0 Pressure vessel with an inner diameter of 50 mm and an inner height of 94.5 mm[\/vc_column_text][vc_row_inner rt_row_style=&#8221;global-style&#8221; rt_bg_custom_alignment=&#8221;top&#8221;][vc_column_inner width=&#8221;1\/2&#8243; rt_column_shadow=&#8221;&#8221; rt_bg_image_repeat=&#8221;repeat&#8221; rt_bg_size=&#8221;auto auto&#8221; rt_bg_attachment=&#8221;scroll&#8221;][vc_btn title=&#8221;Substance Classification&#8221; style=&#8221;classic&#8221; color=&#8221;purple&#8221; i_icon_fontawesome=&#8221;fas fa-angle-left&#8221; add_icon=&#8221;true&#8221; link=&#8221;url:%2Fen%2Fbenefits%2Fsubstance-classification%2F|title:Substance%20classification&#8221; el_class=&#8221;btn&#8211;red&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243; rt_column_shadow=&#8221;&#8221; rt_bg_image_repeat=&#8221;repeat&#8221; rt_bg_size=&#8221;auto auto&#8221; rt_bg_attachment=&#8221;scroll&#8221;][vc_btn title=&#8221;Benefits&#8221; style=&#8221;classic&#8221; color=&#8221;purple&#8221; i_icon_fontawesome=&#8221;fas fa-angle-left&#8221; add_icon=&#8221;true&#8221; link=&#8221;url:%2Fen%2Fbenefits%2F|title:Benefits&#8221; el_class=&#8221;btn&#8211;red&#8221;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row rt_row_background_width=&#8221;fullwidth&#8221; rt_row_content_width=&#8221;default&#8221; rt_row_style=&#8221;default-style&#8221; rt_row_borders=&#8221;&#8221; rt_row_shadows=&#8221;&#8221; rt_row_paddings=&#8221;true&#8221; rt_bg_effect=&#8221;classic&#8221; rt_bg_image_repeat=&#8221;repeat&#8221; rt_bg_size=&#8221;cover&#8221; rt_bg_position=&#8221;right top&#8221; rt_bg_attachment=&#8221;scroll&#8221; rt_bg_video_format=&#8221;self-hosted&#8221;][vc_column width=&#8221;1\/3&#8243; rt_column_shadow=&#8221;&#8221; rt_bg_image_repeat=&#8221;repeat&#8221; rt_bg_size=&#8221;auto auto&#8221; rt_bg_attachment=&#8221;scroll&#8221; class=&#8221;download&#8221; rt_bg_color=&#8221;&#8221; rt_bg_overlay_color=&#8221;&#8221; offset=&#8221;vc_hidden-sm vc_hidden-xs&#8221; css=&#8221;.vc_custom_1529335398592{padding-bottom: 0px !important;}&#8221; rt_padding_bottom=&#8221;0&#8243;][vc_widget_sidebar sidebar_id=&#8221;rt-theme-20-common-sidebar&#8221;][\/vc_column][vc_column width=&#8221;2\/3&#8243; rt_column_shadow=&#8221;&#8221; rt_bg_image_repeat=&#8221;repeat&#8221; rt_bg_size=&#8221;auto auto&#8221; rt_bg_attachment=&#8221;scroll&#8221; class=&#8221;maincontent&#8221; rt_bg_color=&#8221;&#8221; rt_bg_overlay_color=&#8221;&#8221; css=&#8221;.vc_custom_1531993670525{padding-bottom: 2em !important;}&#8221;][vc_column_text el_class=&#8221;redborderleft&#8221;] Dutch pressure vessel test: UN Series E, Test E.2 For the test,  &#8230;<br \/><a class=\"more-link\" href=\"https:\/\/consilab.de\/en\/benefits\/substance-classification\/dutch-pressure-vessel-test\/\">more | mehr<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":3916,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-11407","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/pages\/11407","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/comments?post=11407"}],"version-history":[{"count":1,"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/pages\/11407\/revisions"}],"predecessor-version":[{"id":12150,"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/pages\/11407\/revisions\/12150"}],"up":[{"embeddable":true,"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/pages\/3916"}],"wp:attachment":[{"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/media?parent=11407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}