{"id":17966,"date":"2026-11-10T13:28:58","date_gmt":"2026-11-10T12:28:58","guid":{"rendered":"https:\/\/consilab.de\/?p=17966"},"modified":"2026-11-10T13:28:58","modified_gmt":"2026-11-10T12:28:58","slug":"consiletter-9","status":"publish","type":"post","link":"https:\/\/consilab.de\/en\/consiletter-9\/","title":{"rendered":"consiLetter 9: \u201cChristmas tree safety hazard\u201d \u2013 supply line pressure loss before safety valves"},"content":{"rendered":"<p>[vc_row rt_row_background_width=&#8221;fullwidth&#8221; rt_row_content_width=&#8221;default&#8221; rt_row_style=&#8221;default-style&#8221; rt_row_borders=&#8221;&#8221; rt_row_shadows=&#8221;&#8221; rt_row_paddings=&#8221;true&#8221; rt_bg_effect=&#8221;classic&#8221; rt_bg_image_repeat=&#8221;repeat&#8221; rt_bg_size=&#8221;cover&#8221; rt_bg_position=&#8221;right top&#8221; rt_bg_attachment=&#8221;scroll&#8221; rt_bg_video_format=&#8221;self-hosted&#8221; class=&#8221;with_sidebar&#8221;][vc_column width=&#8221;1\/4&#8243; rt_column_shadow=&#8221;&#8221; rt_bg_image_repeat=&#8221;repeat&#8221; rt_bg_size=&#8221;auto auto&#8221; rt_bg_attachment=&#8221;scroll&#8221; css=&#8221;.vc_custom_1782376114778{padding-top: 0px !important;}&#8221; rt_bg_color=&#8221;&#8221; rt_bg_overlay_color=&#8221;&#8221;][vc_widget_sidebar sidebar_id=&#8221;ca-sidebar-15951&#8243; el_class=&#8221;consiletter__sidebar&#8221;][\/vc_column][vc_column width=&#8221;3\/4&#8243; rt_column_shadow=&#8221;&#8221; rt_bg_image_repeat=&#8221;repeat&#8221; rt_bg_size=&#8221;auto auto&#8221; rt_bg_attachment=&#8221;scroll&#8221; css=&#8221;.vc_custom_1782378935763{padding-top: 0px !important;}&#8221; rt_bg_color=&#8221;&#8221; rt_bg_overlay_color=&#8221;&#8221; class=&#8221;consiletter__letter&#8221;][vc_column_text css=&#8221;&#8221;]<strong>consiletter 9<\/strong><\/p>\n<h1>\u201cChristmas tree safety hazard\u201d \u2013 supply line pressure loss before safety valves<\/h1>\n<p>Where there were not enough free vessel connecting pieces, production plant supply lines for various media frequently used to be connected using T-pieces in so-called \u201cChristmas trees\u201d and routed through a common line on one connecting piece. Since a safety valve ideally never responds, it must \u2013 unlike the valves of the supply lines \u2013 merely be easily accessible during maintenance, which occurs on average every two years. Thus, safety valves can often be seen as on the picture at the left, connected far to the back of the Christmas tree. In reality, however, in almost every case where this arrangement is used, the pressure loss of the line is too high \u2013 except when the nominal size of the \u201ctree\u201d is significantly larger than the nominal inlet size.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-17970\" src=\"https:\/\/consilab.de\/wp-content\/uploads\/2026\/11\/consiletter-9-Bild-350x211.jpg\" alt=\"\" width=\"350\" height=\"211\" srcset=\"https:\/\/consilab.de\/wp-content\/uploads\/2026\/11\/consiletter-9-Bild-350x211.jpg 350w, https:\/\/consilab.de\/wp-content\/uploads\/2026\/11\/consiletter-9-Bild-768x462.jpg 768w, https:\/\/consilab.de\/wp-content\/uploads\/2026\/11\/consiletter-9-Bild.jpg 836w\" sizes=\"auto, (max-width: 350px) 100vw, 350px\" \/><\/p>\n<p>The longer the section of pipeline that the medium must flow through to the inlet of the safety valve, the greater the pressure loss. Each forced change in direction in this area (bend, T-piece) results in additional pressure loss. To limit the pressure loss in the line to the safety valve, the line should therefore be as short as possible and be straight (see illustration below).<\/p>\n<p>The pertinent regulations, such as the AD2000 data sheet A2 or the DIN-EN-ISO 4126 part 9, stipulate the maximum allowable supply line pressure loss in front of safety valves: Pressure loss in the supply line must not exceed 3% of the excess set pressure of the valve. Furthermore, both regulations require that supply lines to safety valves generally be short and \u2013 if possible \u2013 straight. In addition, pressure loss is to be calculated with the maximum mass flux that can be discharged via the safety valve, which may be significantly greater in some cases than the required mass flux (\u201cto be discharged\u201d) for pressure release.<\/p>\n<p>The necessity of limiting the supply line pressure loss is based on the fact that excessive pressure loss can lead to a high-frequency opening and closing, or \u201cfluttering,\u201d of the safety valve. This fluttering not only prevents reliable operation of the safety valve and reduces the dischargeable mass flux, it can also lead to mechanical destruction of the safety valve and furthermore cause the entire plant to vibrate.<\/p>\n<p>In the case that a longer supply line with changes of direction is necessary for operational reasons, or that a rupture disk or switch valve is to be installed before the safety valve, the supply line to the safety valve must be designed to be one or more nominal sizes larger than the safety valve inlet. If the safety valve is oversized, the dischargeable mass flux of the safety valve can be reduced by using a stroke limitation, thereby reducing supply line pressure loss.<\/p>\n<style>\n.picpoints-player[data-id='17949'] {\n\twidth: 100%;\n\theight: 400px;\n}\n<\/style>\n<div data-id='17949' data-scene-id='' class='picpoints-player' role='application' aria-label='PicPoints Player'><\/div>\n<p>Explanations of vibration behavior of safety valves due to high supply line pressure loss as well as recommendations for avoiding excessive pressure loss are described here, for example (in German):<\/p>\n<p><em>Westphal, F., Christ, M.: Erfahrungen aus der Praxis mit dem 3 %-Kriterium f\u00fcr die Zuleitungen von Sicherheitsventilen, Technische Sicherheit Bd. 4 (2014), No. 3<\/em><\/p>\n<p>If we can assist you with a similar issue, please contact us. Our experts will be happy to help you.<\/p>\n<hr \/>\n<h2>Your contacts<\/h2>\n<div class=\"consiLetter__footer\">\n<div><strong>Frankfurt<\/strong><br \/>\nTel.: +49(0)69 305 30013<br \/>\nE-Mail: <a href=\"mailto:kontakt@consilab.de\">kontakt@consilab.de<\/a><\/div>\n<div><strong>Leverkusen<\/strong><br \/>\nTel.: +49(0)214 2605 56458<br \/>\nE-Mail: <a href=\"mailto:kontakt@consilab.de\">kontakt@consilab.de<\/a><\/div>\n<\/div>\n<hr \/>\n<p>[\/vc_column_text][vc_row_inner rt_row_style=&#8221;global-style&#8221; rt_bg_custom_alignment=&#8221;top&#8221;][vc_column_inner width=&#8221;1\/2&#8243; rt_column_shadow=&#8221;&#8221; rt_bg_image_repeat=&#8221;repeat&#8221; rt_bg_size=&#8221;auto auto&#8221; rt_bg_attachment=&#8221;scroll&#8221; css=&#8221;.vc_custom_1782905286853{margin-top: 0px !important;border-top-width: 0px !important;padding-top: 0px !important;}&#8221; rt_bg_color=&#8221;&#8221; rt_bg_overlay_color=&#8221;&#8221;][vc_btn title=&#8221;consiletter 8&#8243; style=&#8221;classic&#8221; color=&#8221;purple&#8221; align=&#8221;left&#8221; i_icon_fontawesome=&#8221;fa fa-solid fa-angle-left&#8221; css=&#8221;&#8221; add_icon=&#8221;true&#8221; link=&#8221;url:%2Fen%2Fconsiletter-8%2F|title:consiletter%201&#8243; el_class=&#8221;btn&#8211;red&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243; rt_column_shadow=&#8221;&#8221; rt_bg_image_repeat=&#8221;repeat&#8221; rt_bg_size=&#8221;auto auto&#8221; rt_bg_attachment=&#8221;scroll&#8221; css=&#8221;.vc_custom_1782905294826{margin-top: 0px !important;border-top-width: 0px !important;padding-top: 0px !important;}&#8221; rt_bg_color=&#8221;&#8221; rt_bg_overlay_color=&#8221;&#8221;][vc_btn title=&#8221;consiletter 10&#8243; style=&#8221;classic&#8221; color=&#8221;purple&#8221; align=&#8221;right&#8221; i_align=&#8221;right&#8221; i_icon_fontawesome=&#8221;fa fa-solid fa-angle-right&#8221; css=&#8221;&#8221; add_icon=&#8221;true&#8221; link=&#8221;url:%2Fen%2Fconsiletter-10%2F|title:consiletter%201&#8243; el_class=&#8221;btn&#8211;red&#8221;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The consilLetter deals with supply pressure losses upstream of safety valves caused by long pipework &#8230;<br \/><a class=\"more-link\" href=\"https:\/\/consilab.de\/en\/consiletter-9\/\">more | mehr<\/a><\/p>\n","protected":false},"author":10,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[44],"tags":[],"class_list":["post-17966","post","type-post","status-publish","format-standard","hentry","category-consiletter-en"],"_links":{"self":[{"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/posts\/17966","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/comments?post=17966"}],"version-history":[{"count":2,"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/posts\/17966\/revisions"}],"predecessor-version":[{"id":17977,"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/posts\/17966\/revisions\/17977"}],"wp:attachment":[{"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/media?parent=17966"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/categories?post=17966"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/consilab.de\/en\/wp-json\/wp\/v2\/tags?post=17966"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}